0330-0410-0M Rev D
•
Portable Digital Truck Scale
7
INSTALLATION
At this point, the concrete slab or piers shall be in place as specified on the certified Pier Plan
drawing.
The top of piers shall be in a level plane and a
minimum of 4 inches above the ground line.
NOTE:
Make sure the slab or top of piers are
clear of debris and rough spots before setting
the scale sections in place.
Clear away any rough spots or debris on
concrete slab or top of piers.
NOTE:
1.
Fill for the approaches shall be placed so that the fill does not interfere with any of the scale
mechanism.
2.
It is recommended on a scale installed in any one location for a period of six months or
more, on the approach end or ends, there shall be a straight and level approach as follows:
(A) At least the width of the platform.
(B) At least one-half the length of the platform, but not required to be more than 40 feet.
(C) Not less than 10 feet of any approach adjacent to the platform shall be constructed
of concrete or similar durable material to ensure that this portion remains smooth
and level and in the same plane as the platform. However, grating of sufficient
strength to withstand all loads may be installed in this portion; and further where
deemed necessary for drainage purposes, the remaining portion of the approach
may slope slightly.
WARNING! Permanent damage may occur if the portable truck scale is not
properly installed.
Summary of Contents for ARMOR
Page 2: ...0330 0410 0M Rev D Portable Digital Truck Scale 2...
Page 4: ...0330 0410 0M Rev D Portable Digital Truck Scale II...
Page 8: ...0330 0410 0M Rev D Portable Digital Truck Scale VI...
Page 14: ...0330 0410 0M Rev D Portable Digital Truck Scale 6 Scale Site Cont...
Page 126: ...0330 0410 0M Rev D Portable Digital Truck Scale 118 PARTS IDENTIFICATION...
Page 133: ...0330 0410 0M Rev D Portable Digital Truck Scale 125 Decal and Name Plate Mounting View Detail...