SETUP AND CALIBRATION, CONT.
Dual-Point without Zero (False Zero) Calibration
CAL1=
– FIRST CALIBRATION WEIGHT
The display will show
CAL1
=0
. This is the first of two calibration steps. This weight is the
TEST WEIGHTS / TEST LOAD.
Place the weights on the scale platform.
Using the numeric keys, input the value of the calibrated test weights / test load and
then press the
ENTER
key.
NOTE!
When entering values for
CAL1=,
the digits start
displaying on the right side of the display and proceed to the left. When large values
are used (more than 3 digits), the
CAL1=
prompt will automatically scroll off the left side
of the display to show the additional digits on the right as they are entered.
Starting at the left and proceeding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the
display will show:
CAL2=
.
CAL2=
- SECOND CALIBRATION WEIGHT
The display will show
CAL2
=0
. This is the second of two calibration steps.
Remove the weights on the scale platform and then press the
NET/GROSS
key.
Starting at the left and proceeding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the display
will show:
Sio?
.
Summary of Contents for 212G
Page 2: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 2 ...
Page 10: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 6 INSTALLATION CONT Figure No 2 ...
Page 27: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 23 Lamp test on power up ...
Page 52: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 48 ...