8200-M628-O1 Rev A
212G/212GX Installation & Technical
Page 21
SETUP AND CALIBRATION, CONT.
DO NOT operate the keypad with pointed objects (pencils, pens, etc).
Damage to keypad resulting from this practice is NOT covered under warranty.
During the setup and calibration process it is necessary to enter operational parameters via the
indicators’ keypad. Pressing the
ENTER
key without entering a new value will retain the
current setting and advance to the next prompt. To change a setting, enter a new value and
press the
ENTER
key. This will save the new value and advance to the next prompt. Pressing
the
*
(
ASTERISK)
key will "backup" to the previous prompt.
. Press the
ENTER
key to select the parameters in each main menu.
NOTE! Setup may be interrupted at any time. ALL data previously entered
and finalized with the ENTER key will be retained in the non-volatile memory.
Pressing the calibration switch
at any prompt
will return you to the
SEtUP
menu. By pressing
and releasing the calibration switch at the
SetUP
prompt, you may skip to any other section To
exit setup, press the
*
key with any of the above menu selections displayed or cycle power at
any time (press the
ON/OFF
key twice).
SEtUP
USA=
(Domestic or International)
With
SEtUP
displayed, press the
ENTER
key. The display will change to
USA=
. Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys,
0/NO
or
1/YES
, enter the new setting
and then press the
ENTER
key to save it.
USA=YES
(Domestic)
USA=NO
(International)
Date
=
mm/dd/yy
Date
=
dd/mm/yy
Trl
= no
Trl= yes
Cap
+ 4% to OC
Cap
+ 9 grads to OC
PT printed with tare
Lamp test on power up
If you selected
USA = 0
(International), an additional prompt,
PASS=
will be displayed.
If you selected
USA = 1
(Domestic) proceed to
LFt
=
(Legal For Trade).
NOTE!
With the exception of the
SEtUP
prompt, the prompts displayed for each section
are different if you push the calibration switch instead of pressing the
ENTER
key to
proceed through the section.
For example
, if you press the calibration switch with the
SEtUP
displayed, the next prompt displayed will be
A-d
. If you step through the setup
prompts by pressing the
ENTER
key, the next prompt displayed will be
A-d?
. In addition,
at a prompt with the question mark (
?
) displayed, you must press the
ENTER
key, the
1/YES
key and then the
ENTER
key again to proceed with that section. To skip the
section and advance to the next menu selection, press the
ENTER
key twice.
Summary of Contents for 212G
Page 2: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 2 ...
Page 10: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 6 INSTALLATION CONT Figure No 2 ...
Page 27: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 23 Lamp test on power up ...
Page 52: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 48 ...