8200-M628-O1 Rev A
212G/212GX Installation & Technical
Page 16
KEYPAD FUNCTIONS, CONT.
PRESET KEY
This key is used to enter the weight values for the three preset weight comparators or for the
checkweigher feature depending on which feature was selected (setup parameter
D out
)
during setup and calibration.
Preset Weight Comparator
If the Preset Weight Comparator feature was selected in the
SETUP
menu, and the
PRESET
key pressed, the display will show
PSET1=
. Press the
ENTER
key and the currently stored
value for the number 1 preset weight comparator will be displayed. If the value displayed is
acceptable, press the
ENTER
key, otherwise, use the numeric keys to enter the new preset
value and press the
ENTER
key. The display will show
PSET2=
if 2 or 3 active presets were
selected in
SETUP
.
Press the
ENTER
key and the currently stored value for the number 2
preset weight comparator will be displayed. As before, if the value displayed is acceptable,
press the
ENTER
key, otherwise, use the numeric keys to enter the new value and press
the
ENTER
key. The display will show
PSET3=
if 3 active presets were selected in
SETUP
.
Press the
ENTER
key and the currently stored value for the number 3 preset weight
comparator will be displayed. As before, if the value displayed is acceptable, press the
ENTER
key, otherwise, use the numeric keys to enter the new value and press the
ENTER
key.
Checkweigher (Can be used with 2XX-OU, Checkweigher Light Bar Option)
If the Checkweigher feature was selected and the
PRESET
key pressed, the display will
show
UNDER=
. Press the
ENTER
key and the currently stored value for the minimum
acceptable weight will be displayed. Press the
ENTER
key if the displayed value is correct
or use the numeric keys and enter the new value and press the
ENTER
key. The display will
show
OVER=
. Press the
ENTER
key and the currently stored value for the minimum
acceptable over weight will be displayed. As before, if the value shown is correct, press the
ENTER
key. If the value is incorrect, enter the new value and press the
ENTER
key to save
it.
Note: the
OVER=
.
value must be greater than the
UNDER=
value.
Remember that both the preset weight comparators and checkweigher
functions operate on the absolute value of weight ignoring the polarity.
After the last preset value is entered, the indicator will return to normal
operation.
Summary of Contents for 212G
Page 2: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 2 ...
Page 10: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 6 INSTALLATION CONT Figure No 2 ...
Page 27: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 23 Lamp test on power up ...