Before commencing with the installation of this appliance make sure 

that you have read the following instructions carefully.

In particular familiarise yourself with the safety devices required by 

the system, only then will you be able to use them to great effect.

Not all of the safety devices required by Italian or local safety stand-

ards have been taken into consideration in this manual.

The installer must make sure that any eventual safety devices re-

quired by the local standards and regulations have been installed 

both ahead of and after the products described in this manual.

This appliance must be used exclusively for the purpose for which 

it has been made. Any non authorised modifications are to be con-

sidered improper and therefore dangerous. 

These instructions are aimed at professionally qualified “install-

ers of electrical equipment” in conformity with the standard “Nr. 

46/5.3.1990”.

The  manufacturer  accepts  no  liability  for  damage  caused  by,  or 

situations arising from, the improper use of these appliances and 

therefore all work carried out after the delivery of the appliance is to 

be considered the complete responsibility of the installer. 

Appendix A

Communications parameters

Using a P.C. fitted with a serial port controller the following parameters are 
required

Speed:  1200 … 9600
Data bits: 

8

Parity:   

None

Stop bits: 

1

Duplex:  Full
Emulation: 

VT100

Mode:   

Answer 

  

 

 

 

 

 

 

 

   

Summary of Contents for ACD-148

Page 1: ...number_ _________________ Applicable security N Note Photoelectric cells Pneumatic safety tubes ______________ ____________________________ Luminous warning lights_____________ ______________________...

Page 2: ...ual This appliance must be used exclusively for the purpose for which it has been made Any non authorised modifications are to be con sidered improper and therefore dangerous These instructions are ai...

Page 3: ...Elettronica S p A LISTS 1 ENABLED USER LIST 2 FORMER EVENTS LIST 3 END ENTER Il D1 Enabled user list This list is the same as that obtained using option 8 from menu level B D2 Former events list The...

Page 4: ...required The liquid crystal display allows you to follow all the operations performed by the device and verify the completion of each action When an enabled code is received one of the 4 internal rela...

Page 5: ...on frequency 27 195 MHz local oscillation frequency 27 650 MHz local oscillation frequency 30 p p m from 10 to 55 C intermediate frequency 455 KHz impedance in input 50 sensibility with a finely tuned...

Page 6: ...lows you to disable a user temporarily without having to erase the information from memory B7 Modifying the enable status of a particular channel To modify the enable status of a particular channel ch...

Page 7: ...e appears on the screen ARE YOU SURE Y N If the answer Y is given the following message appears CODE E N A B L E D TYPE ESC to EXIT In this way the user is enabled this operation is only useful if the...

Page 8: ...l D Activated at 18 00 02 END of LIST 13 1 25 14 5 1 9 6 5 1 9 6 5 1 9 6 RS232 RS232 DB9 DB9 DB9 DB25 DB9 DB25 8 25 By choosing option 2 from menu level B you can add the name of the user This option...

Page 9: ...1F451B207C Type the code into the terminal only using uppercase letter and then press CR If the code is wrong the code also carries redundant information to facilitate the checksum the following messa...

Page 10: ...tter indi cating the month A4 Modifying the password To personalise the system password choose Nr 4 from the System Menu The following message appears on the display CHANGE PASSWORD ARE YOU SURE Y N I...

Page 11: ...tter pressing CHA key code Section A of the TX pressing CHB key code Section B of the TX pressing CHC key code Section C of the TX pressing CHD key code Section D of the TX If the answer Y is given th...

Page 12: ...the following question will appear ARE YOU SURE Y 14 Repeatedly pressing the SET button will alternate between N Y etc A System menu Choose Nr 1 from the main menu to enter the system menu The follow...

Page 13: ...the connections have been car ried out as shown in fig 4 pag 8 and the correct communication parameters have been set see appendix A press the TAB key on the keyboard If the communication is correct t...

Page 14: ...the memorisation stage channel enabled or disabled follow the user code deletion instructions Step B up to point 7 ON LINE FUNCTION Once the ACD 148 has been installed the four I O ports can only be a...

Page 15: ...with the following message ERASE ALL CODES ARE YOU SURE Y ENABLING AND DISABLING CHANNELS IN DIFFERENT ZONES By means of the 4 way dip switch located inside the container towards the rear of the p c...

Page 16: ...ELETTRONICA S p A ENABLED USER LIST CODE N CHA CHB CHC CHD ENABLED DISABLED USER NAME 0 0 0 0 y y y y E MR JONES 0 0 0 1 Y Y Y Y E ROBERT HALL 0 0 0 2 Y Y Y Y D V MACINTIRE 0 0 0 3 Y Y Y Y E HENRY LLO...

Reviews: