SYSTEM INITIALIZATION

To initialize the system proceed as follows:

A.  

Move the 4 dip-switches (fig.2 page.7) to the “OFF” position 

B.  

Simultaneously press the MODE and MEMO keys

The following will occur:

 

B1. System clock reset

     

B2. BAUD RATE set to 1200 BAUD

 

B3. Generic password set to  “12345678”.

C.  

If all is well the display will indicate the message: 

 

“INIT MEMORY”;

D.  

Simultaneously press the SET and MEMO keys

     

 This will reset the former events buffer memory;

E.  

If all is well the display will indicate the message:  

 

“DELETING FORMER EVENTS”;

F.  

Move the 4 dip-switches to the “ON” position

G.  

Press the RESET button.

C  A  R  D  I  N 

***** ACD-148 ***** 

In its normal operating mode the ACD-148 does not require enabling via the 

serial key; this key is only required when system management tasks are to be 

carried out (memorising new user codes, cancelling codes, setting the date and 

time etc.).

SETTING THE CLOCK

1. Simultaneously press the MODE and SET keys

2. The display will show the following :

 

 

 

YY  MM  DD  HH  MM

                                            0

3. Press the SET key several times scrolling the digits relative to the years (80,S-

90,s etc.).

4.  Once the desired number is reached (e.g. 9 ) press the MODE key; 

The cursor prompt will then move to the single year units and a starting “0” will 

be shown.

5. Press the SET key once again and repeat the instructions at point 3 until the 

year has been set.  

 

6. Press the MODE key  again and the cursor prompt will move to the letter indi-

cating the month

A4.  Modifying the password

To personalise the system password choose Nr. 4 from the System Menu.

The following message appears on the display:

 

 

!! CHANGE PASSWORD!! ARE YOU SURE? [Y/N] >>

If the answer Y is given the following message appears on the display:

 

 

 

ENTRY NEW PASSWORD[ 8 characters ] >> . . . . . . . 

ATTENTION: You must insert an eight digit password 

To avoid typing errors the password is asked for a second time and if the two 

passwords do not conform the following message appears on the display:

            

 

 

WRONG PROCEDURE!!   - PASSWORD UNCHANGED 

               

TYPE < ESC > to EXIT

B.   USER MANAGEMENT

Choose Nr. 2 from the main menu to enter the user management menu :

The following menu appears on the screen:

C A R D I N    ACD-148    V. 3102  (1994)    Cardin Elettronica S.p.A.

 **** USERS MANAGEMENT ****

 

1. ADD USERS 

 

6. DISABLE USER CODE

 

2. ADD USER NAME 

 

7. CHANNEL SETTINGS

 

3. CHANGE USER NAME  8. ENABLED USERS LIST

 

4. DELETE USER CODE 

9. END

 

5. ENABLE USER CODE

           ENTER >>>

This menu features all the user management tools which can be operated from a 

remote station.

For each individual user the system is able to memorise the following data:

- an internal identification code number, the enabled status for each channel and each 

code, and  a 12 character string for generic data  ( the name of the user etc.).

The possibility to memorise a new user from a remote terminal is also possible if 

you possess the “ CARDIN ACD-248”. This device is a remote display which al-

lows you to  read the S48 transmitter code number, which can then be inserted 

into the terminal

B1.  Programming a new user code

Choose Nr. 1 from the management menu.

The following message appears on the screen:

Summary of Contents for ACD-148

Page 1: ...number_ _________________ Applicable security N Note Photoelectric cells Pneumatic safety tubes ______________ ____________________________ Luminous warning lights_____________ ______________________...

Page 2: ...ual This appliance must be used exclusively for the purpose for which it has been made Any non authorised modifications are to be con sidered improper and therefore dangerous These instructions are ai...

Page 3: ...Elettronica S p A LISTS 1 ENABLED USER LIST 2 FORMER EVENTS LIST 3 END ENTER Il D1 Enabled user list This list is the same as that obtained using option 8 from menu level B D2 Former events list The...

Page 4: ...required The liquid crystal display allows you to follow all the operations performed by the device and verify the completion of each action When an enabled code is received one of the 4 internal rela...

Page 5: ...on frequency 27 195 MHz local oscillation frequency 27 650 MHz local oscillation frequency 30 p p m from 10 to 55 C intermediate frequency 455 KHz impedance in input 50 sensibility with a finely tuned...

Page 6: ...lows you to disable a user temporarily without having to erase the information from memory B7 Modifying the enable status of a particular channel To modify the enable status of a particular channel ch...

Page 7: ...e appears on the screen ARE YOU SURE Y N If the answer Y is given the following message appears CODE E N A B L E D TYPE ESC to EXIT In this way the user is enabled this operation is only useful if the...

Page 8: ...l D Activated at 18 00 02 END of LIST 13 1 25 14 5 1 9 6 5 1 9 6 5 1 9 6 RS232 RS232 DB9 DB9 DB9 DB25 DB9 DB25 8 25 By choosing option 2 from menu level B you can add the name of the user This option...

Page 9: ...1F451B207C Type the code into the terminal only using uppercase letter and then press CR If the code is wrong the code also carries redundant information to facilitate the checksum the following messa...

Page 10: ...tter indi cating the month A4 Modifying the password To personalise the system password choose Nr 4 from the System Menu The following message appears on the display CHANGE PASSWORD ARE YOU SURE Y N I...

Page 11: ...tter pressing CHA key code Section A of the TX pressing CHB key code Section B of the TX pressing CHC key code Section C of the TX pressing CHD key code Section D of the TX If the answer Y is given th...

Page 12: ...the following question will appear ARE YOU SURE Y 14 Repeatedly pressing the SET button will alternate between N Y etc A System menu Choose Nr 1 from the main menu to enter the system menu The follow...

Page 13: ...the connections have been car ried out as shown in fig 4 pag 8 and the correct communication parameters have been set see appendix A press the TAB key on the keyboard If the communication is correct t...

Page 14: ...the memorisation stage channel enabled or disabled follow the user code deletion instructions Step B up to point 7 ON LINE FUNCTION Once the ACD 148 has been installed the four I O ports can only be a...

Page 15: ...with the following message ERASE ALL CODES ARE YOU SURE Y ENABLING AND DISABLING CHANNELS IN DIFFERENT ZONES By means of the 4 way dip switch located inside the container towards the rear of the p c...

Page 16: ...ELETTRONICA S p A ENABLED USER LIST CODE N CHA CHB CHC CHD ENABLED DISABLED USER NAME 0 0 0 0 y y y y E MR JONES 0 0 0 1 Y Y Y Y E ROBERT HALL 0 0 0 2 Y Y Y Y D V MACINTIRE 0 0 0 3 Y Y Y Y E HENRY LLO...

Reviews: