MAP2
Page 9 of 32
Installation Manual
September 2020 • Rev. 1.5
3.
The MAP2 allows for the control of up to 8 door combinations. Ensure that
adequate 12V DC power and current is available, especially when the same
power supply is used for the locks.
See suggested power supplies in Appendix section
.
4.
It is highly recommended to use a separate power supply for locks as they
require a high amount of current for proper operation.
Network Information:
1.
The MAP2 Controller is set to acquire an IP address automatically (
DHCP).
However, it can be optionally set to a static IP address or reset if necessary.
See
Appendix section for more information.
Mechanical Information
:
1.
If required, the MAP2 may be mounted inside of a lockable enclosure such as
the CA-MAP2ENCL if access is to be limited to the external connections.
2.
If a Lockable external enclosure is used and a Tamper switch is available as in
the CA-MAP2ENCL, the
MAP2 has a Panel Tamper
input connection available.
Connecting the Tamper
switch to this input will
produce an Alarm when
opening and closing the
enclosure. This Alarm is sent
to the Host computer.
Figure 3
Figure 4