MAP2
Page 26 of 32
Installation Manual
September 2020 • Rev. 1.5
10.
The factory default or current password for a new unconfigured MAP2 panel is
Cansec
. The password must be changed to something else other than
Cansec
.
11.
Click
Save
. The panel saves the new settings and reboots for the settings to take
effect.
USB IP CONFIGURATION TOOL
1.
If the MAP2 controller is already powered off then proceed to step 3. Otherwise,
press and hold the SHDN button until the STAT LED on the module begins
flashing rapidly then release the shutdown SHDN button.
2.
Wait until the MAP2 does a complete shutdown, indicated by the status STAT
LED going to the OFF state (except the Power LED). Unplug the power connector.
Figure 22
Insert a USB flash drive into one of
the USB ports
Important
:
Shutdown Push
Button (SHDN)
must be used to avoid
data corruption on
the MAP2 controller
.