MAP2
Page 8 of 32
Installation Manual
September 2020 • Rev. 1.5
Important Installation Notes
Controller Provisioning Options:
The MAP2 controller is provisioned with the default 2-door configuration. However,
the door configuration can be upgraded. The MAP2 can run only in one mode either
First Access
or
CloudACS
. Door configurations are as follow:
a.
2–door configuration: 2 lock relays, 2 multi-function relays, 2 REX/RTE, 2
door contacts/DPS, 12 general-purpose
input points and 12 general-purpose
output points.
b.
4–door configuration: 4 lock relays, 4 multi-function relays, 4 REX/RTE, 4
door contacts/DPS, 8 general-purpose
input points and 8 general-purpose
output points.
c.
6– door configuration: 6 lock relays, 6 multi-function relays, 6 REX/RET, 6
door contacts/DPS, 2 general-purpose
input points and 2 general-purpose
output points.
d.
8–door configuration: 8 lock relays, 8 multi-fucntion relays, 8 REX/RET, 8
door contacts/DPS, 0 general-purpose
input point and 0 general-purpose
output point.
Elevator Configuration
: See MAP2 Elevator Controller Installation Guide
Electrical Information:
1.
The MAP2 utilizes a mini-computer and
must be operated using a battery
backed up power supply
to protect the hardware, system files and data files
from corruption due to power outage.
See Note 1 in Appendix section.
2.
CAUTION
: Do not unplug the
MAP2 Power connector if the
system is in operation as data
corruption may occur on the
MAP2 mini-computer. Please
follow the instructions from the
section “
Shutdown Button
”.
Figure 2
Summary of Contents for MAP2
Page 1: ...MAP2 Controller INSTALLATION MANUAL September 2020...
Page 7: ...MAP2 Page 7 of 32 Installation Manual September 2020 Rev 1 5 MAP2 Controller Layout Figure 1...
Page 19: ...MAP2 Page 19 of 32 Installation Manual September 2020 Rev 1 5 Output Wiring Figure 14...
Page 32: ...MAP2 Page 32 of 32 Installation Manual September 2020 Rev 1 5...