49
Status of the Buttons
• Function:
To get the status of the buttons on the operation panel .
• Timing of the “C-response Packet” sent to the PC:
Right after this command is received by the
RE-350
.
• The parameter of the “C-response Packet”:
The bit assignment to each status to explain the
RE-350
’s condition.
D15 D14 D13 D12 D11 D10 D9 D8
D7 D6 D5 D4 D3 D2 D1 D0
0
0 Focus
B/W
W/B
NEGA Input
RS-232
Auto
Select
Control
• The maximum operation time (msec):
100 millisecond
• Command format:
Header
ID number
Command Parameter MSH Parameter LSH
$10 $ 8 *
$ 8 1 $ 0 0 $ 0 0
0
0 Backlight
Lights Zoom
Zoom Focus Focus
TELE
WIDE
FAR
NEAR
Summary of Contents for RE-350
Page 1: ...1 RE 350 Control Interface Commands RE 350 Video Visualizer VISUAL COMMUNICATION SYSTEMS v1 0 ...
Page 55: ...55 5 1 RS 232C Control Cable Pin Assignment 5 0 Control Cable Pin Assignments RE 350 RE 350 ...