48
Note:
1 = ON
0 = OFF
C MODE 1
and
C MODE 0
explain the operational mode of the
RE-350
as follows:
MODE
C MODE 1 C MODE 0
O
FF
-L
INE
– –
– –
O
N
-L
INE
0
1
N
OTIFICATION
1
0
not used
1
1
Status of Group B
• Function:
To get the status data of Group
B
from the
RE-350
.
• Timing of the “C-response Packet” sent to the PC:
Right after this command is received by the
RE-350
.
• The parameter of the “C-response Packet”:
The bit assignment to each status to explain the
RE-350
’s condition.
0
0 0
0 0
0 0 0
D15 D14 D13 D12 D11 D10 D9 D8
• The maximum operation time (msec):
100 millisecond
• Command format:
Header
ID number
Command Parameter MSH Parameter LSH
$10 $ 8 *
$ 8 0 $ 0 1 $ 0 0
Input
Lights Backlight C MODE C MODE 0 0 0
Camera/Ext ON/OFF ON/OFF 1 0
D7 D6 D5 D4 D3 D2 D1 D0