50
Status of EXP control knob
• Function:
Gets the position data of the
EXP
control knob. (
EXP
= exposure)
• Timing of the “C-response Packet” sent to the PC:
Right after this command is received by the
RE-350
.
• The parameter of the “C-response Packet”:
MSH: $00 fixed
LSH: $00 ~ $FF
• The maximum operation time (msec):
100 millisecond
• Command format:
Header
ID number
Command Parameter MSH Parameter LSH
$10 $ 8 *
$ 82 $ 0 1 $ 0 0
Status of WB control knob
• Function:
Gets the position data of the White Balance Manual control knob.
• Timing of the “C-response Packet” sent to the PC:
Right after this command is received by the
RE-350
.
• The parameter of the “C-response Packet”:
MSH: $00 fixed
LSH: $00 ~ $FF
• The maximum operation time (msec):
100 millisecond
• Command format:
Header
ID number
Command Parameter MSH Parameter LSH
$10 $ 8 *
$ 82 $ 0 0 $ 0 0