Note: Before replacement of the logic board ass'y, check the waste ink amount (by service test print or EEPROM information print). If the
waste ink amount is 7% or more, also replace the ink absorber kit (QY5-0153) when replacing the logic board ass'y. [See
Section 3-3.
Adjustment / Settings, (6) Service mode
, for details.]
2-3. Fax Errors
For errors other than those listed below, please refer to the "
G3 / G4 Facsimile Error Code List (Rev. 2).
"
(1) User error codes
(2) Service error codes
blinking
hard-power-on.
Alarm LED lit
RAM error
[6300]
The RAM error occurred in the RAM check at hard-
power-on.
- Logic board
Error code
TX / RX
Meaning
#001
TX
Document jam
#003
TX / RX
Document is too long, or page time-over
#005
TX / RX
Initial identification (T0 / T1) time-over
#009
RX
Recording paper jam, or no recording paper
#012
TX
No recording paper at the receiving machine
#017
TX
Redial time-over, but no DT detected
#018
TX
Auto dialing transmission error, or redial time-over
#022
TX
Call failed (no dial registration)
#037
RX
Memory overflow at reception of an image
#085
TX
No color fax function supported in the receiving machine
#099
TX / RX
Transmission terminated mid-way by pressing the Stop/Reset button
#995
TX / RX
During TX (sending): Memory transmission reservation cancelled
During RX (receiving): Image data received in the memory cleared
Error code
TX / RX
Meaning
##100
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##101
TX / RX
Sender's modem speed does not match the receiving machine.
##102
TX
Fallback is not available.
##103
RX
EOL has not been detected for 5 seconds (or 15 seconds in CBT).
##104
TX
RTN or PIN has been received.
##106
RX
The procedure signal has been expected for 6 seconds, but not received.
##107
RX
Fallback is not available at the sending machine.
##109
TX
After DCS transmission, a signal other than DIS, DTC, FTT, CFR, or CRP has been received, and re-transmission of the
procedure signal has been attempted the specified number of times but failed.
##111
TX / RX
Memory error
##114
RX
RTN has been received.
##200
RX
A carrier has not been detected for 5 seconds during image reception.
##201
TX / RX
DCN has been received in a method other than the binary procedure.
##204
TX
DTC has been received even when there is no sending data.
##220
TX / RX
System error (main program hang-up)
##224
TX / RX
An error has occurred in the procedure signal in G3 transmission.
##226
TX / RX
The stack pointer has shifted from the RAM area.
##229
RX
The recording area has been locked for 1 minute.
##232
TX
The encoder control unit has malfunctioned.
##237
RX
The decoder control unit has malfunctioned.
##238
RX
The print control unit has malfunctioned.
##261
TX / RX
A system error has occurred between the modem and the system control board.
1-7
Summary of Contents for PIXMA MP830
Page 6: ...Part 1 MAINTENANCE ...
Page 23: ...To the table of contents To the top Part 1 2 LIST OF ERROR DISPLAY INDICATION 1 16 ...
Page 32: ... 12 DF cable cover removal Remove the 2 screws Cable position 1 26 ...
Page 39: ...1 33 ...
Page 40: ...1 34 ...
Page 41: ...1 35 ...
Page 60: ... System data list sample 1 54 ...
Page 61: ... Transmission report sample 1 Transaction number 4 digits 1 55 ...
Page 64: ...Part 2 TECHNICAL REFERENCE ...
Page 79: ...Part 3 APPENDIX ...