
(4) Ink absorber counter setting
Set the ink absorber counter value to a new EEPROM after the logic board is replaced in servicing.
1) Before replacement of the logic board, check the ink absorber counter value in EEPROM information print.
2) After replacement of the logic board, the ink absorber counter value should be set in the service mode using
the Service Tool.
In the
Ink Absorber Counter
section of the Service Tool, select
Main
from the
Absorber
pull-down menu.
From the
Counter Value(%)
pull-down menu, select the value (in 10% increments) which is the closest to
the actual counter value confirmed before replacement of the logic board, and click
Set
.
3) Print EEPROM information to confirm that the value is properly set to the EEPROM.
<3-1. Adjustment>
<3-2. Adjustment and Maintenance in User Mode>
<3-3. Adjustment and Settings in Service Mode>
39 / 52
Summary of Contents for PIXMA iX6550
Page 19: ...5 Remove the panel cover unit R 1 screw 15 52 ...
Page 21: ...4 Remove the printer unit 6 screws Lift the printer unit Specific screw location 17 52 ...
Page 32: ... 10 Cable wiring and connection 1 Logic board and spur unit 28 52 ...
Page 38: ... 2 Service Tool functions Service Tool screen Version 2 000 34 52 ...
Page 39: ...35 52 ...
Page 50: ...4 2 Integrated Inspection Pattern Print Print sample 46 52 ...
Page 51: ...4 3 Ink Absorber Counter Value Print Print sample 4 VERIFICATION AFTER REPAIR 47 52 ...
Page 54: ...50 52 ...