COPIER (Service mode for copier) > FUNCTION (Operation / inspection mode) > INSTALL
RGW-PORT
Setting of UGW port number when using Embedded-RDS
Detail
To set the port number of UGW to be used for Embedded-RDS.
Use Case
When using Embedded-RDS
Adj/Set/Operate Method
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
Display/Adj/Set Range
1 to 65535
Default Value
443
Related Service Mode
COPIER> FUNCTION> INSTALL> ERDS, COM-TEST, COM-RSLT, COM-LOG
Supplement/Memo
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
COM-TEST
Execution of Embedded-RDS communication test
Detail
To execute Embedded-RDS communication test.
If the connection fails, the information is added to the communication error log.
Use Case
When using E-RDS
Adj/Set/Operate Method
Select the item, and then press Yes key.
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
Related Service Mode
COPIER> FUNCTION> INSTALL> ERDS, RGW-PORT, COM-RSLT, COM-LOG
Supplement/Memo
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
COM-RSLT
Display of Embedded-RDS comctn test result
Detail
To display the Embedded-RDS communication test result.
Use Case
When using E-RDS
Adj/Set/Operate Method
N/A (Display only)
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
Display/Adj/Set Range
When not in execution: Unknown
When connection is completed: OK
When connection is failed: NG
Default Value
Unknown
Related Service Mode
COPIER> FUNCTION> INSTALL> ERDS, RGW-PORT, COM-TEST, COM-LOG
Supplement/Memo
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
COM-LOG
Display of Embedded-RDS comctn error log
Detail
To display the Embedded-RDS communication error log.
The dates, times, and error codes of the latest 5 errors that occurred are displayed.
As for the error detail information, the report can be output by executing ERDS-LOG.
Use Case
When using Embedded-RDS
Adj/Set/Operate Method
N/A (Display only)
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
Display/Adj/Set Range
Date: 6 digits
Time: 4 digits
Error code: 8 digits
Related Service Mode
COPIER> FUNCTION> INSTALL> ERDS, RGW-PORT, COM-TEST, COM-RSLT
COPIER> FUNCTION> MISC-P> ERDS-LOG
Supplement/Memo
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
9. Service Mode
286
Summary of Contents for MF735C Series
Page 1: ...Revision 2 0 MF735C Series Service Manual ...
Page 13: ...Product Overview 1 Product Lineup 5 Specifications 7 Parts Name 10 ...
Page 23: ...No Name 6 Home key 7 Stop key 8 NFC Near Field Communication mark 1 Product Overview 14 ...
Page 83: ...Consumable Parts This machine does not have any consumable parts 4 Periodical Service 74 ...
Page 118: ... Procedure 1 Remove the ADF Sensor Unit 2x 5 Parts Replacement and Cleaning 109 ...
Page 144: ... Procedure 1 Remove the Memory Relay PCB 2x 1x 5 Parts Replacement and Cleaning 135 ...
Page 159: ...3 Remove the PCB Holder 3x 4 Remove the Drum Motor 4x 1x 5 Parts Replacement and Cleaning 150 ...
Page 180: ...7 Remove the Registration Unit 2x 5 Parts Replacement and Cleaning 171 ...
Page 181: ...Adjustment 6 Adjustment at Parts Replacement 173 ...
Page 211: ...Troubleshooting 7 Test Print 203 Troubleshooting Items 216 Debug Log 219 ...
Page 230: ...Error Jam Alarm 8 Overview 222 Error Code 225 Jam Code 232 Alarm Code 235 ...
Page 356: ...6 7 8 9 2x 10 1x 10 Installation 347 ...
Page 357: ...11 12 Installing the Card Reader 1 1x M4x16 2 10 Installation 348 ...
Page 358: ...3 4 NOTE Be sure that it does not protrude from the depression 5 6 7 1x 10 Installation 349 ...