■ Safety
For user and service technician's safety, the printer has a function to interrupt 24V power supply to the fixing unit and the high-
voltage power supply unit.
The door switch is turned off and 24V stops under the following condition:
• If the cartridge door is opened (SW301 is turned off)
The printer has the power switch on the DC line so the AC power flows even the power switch is turned off. Be sure to unplug
the power cord before disassembling the printer.
■ Low-voltage power supply unit failure detection
The DC controller determines a low-voltage power supply unit failure, stops +24V1 output and notifies E808 to the Main controller
when it encounters the following condition:
• +24V is higher than a specified voltage
Energy Saving Function
This machine is equipped with energy saving function.
The following shows energy saving status and condition of transition.
Condition
Description
Condition of Transition
Panel off
Turn OFF the panel.
Press [Power key].
Deep sleep
Turn OFF the panel, engine and controller.
(Only the power lamp lights up.)
Transition time to sleep mode has elapsed.
(Default setting: 5 minutes)
* When USB is connected, the machine does not enter deep sleep.
■ Conditions for Not Entering Deep Sleep
Situations in which the machine does not enter sleep mode
• When the machine is in operation
• When the [Processing/Data] indicator is lit up or blinking
• When the machine is performing an operation such as adjustment or cleaning
• When a paper jam occurs
• When the menu screen is displayed
• When an error message is displayed on the screen (There are some exceptions. The machine sometimes enters sleep mode when
error messages are displayed.)
• When the SSID/network key screen for Direct Connection is displayed.
• When settings data is being imported/exported
2. Technology