4
4
4-27
4-27
Parts Replacement and Cleaning Procedure > Main Units > Removing the Stitcher Mount Unit
Parts Replacement and Cleaning Procedure > Main Units > Removing the Stitcher Mount Unit
NOTE:
When installing the saddle unit, install so that the Mylar [1] at the front upper side of
the saddle is on the outside of the delivery guide plate [2] as shown in the figure.
Delivery fault will occur if it goes inside.
[1]
[2]
F-4-54
Removing the Stitcher Mount Unit
1) Remove the front cover.
2) Remove the front inside upper cover. (In the case of Staple Finisher, this procedure is
unnecessary.)
3) Remove the front inside lower cover.
4) Remove the E ring [1], shaft [2], and roller [3].
[1]
[3]
[2]
5) Pull out the stitcher mount unit [1] to the front.
[1]
F-4-55
F-4-56