6
6
6-14
6-14
Installation > Adjusting the Tilt > Check the Tilt
Installation > Adjusting the Tilt > Check the Tilt
Adjusting the Tilt
Check the Tilt
CAUTION:
Depending on the condition of the floor of the site of installation, you may need to
adjust the height or the tilt of the finisher.
A discrepancy in the height or tilt of the finisher can well lead to frequency jams.
Check the height/tilt as follows, and make adjustments as necessary.
F-6-25
1) Check the tilt of front side.
Upper side: Measure the distance [A] of the buffer pass unit upper side and the finisher.
Lower side: Measure the distance [B] of the host machine lower part and the finisher lower
part.
[A]: less than 28.5+/-1mm. [B]: less than 28.5+/-1mm. The difference of [A] and [B] is less
than 1.5mm.
[B]
[A]
F-6-26