0410
The rotation of the K laser
scanner motor is faulty.
The motor lock signal remains in an unlock state for
1 sec or more while the laser scanner motor is in
operation.
E202
A fault has occurred in detecting the No. 1 mirror home position.
0000
The No. 1 mirror base moves in
reverse but does not move to its
home position.
The home position sensor does not go ON within a
specific period of time.
0001
The No. 1 mirror base moves
forward but does not move from
its home position.
The home position sensor does not go OFF within a
specific period of time.
E220
A fault has occurred in activating the scanning lamp.
0000
The intensity of the scanning
lamp has dropped.
During shading adjustment at time of power-on, the
intensity detected by the CCD is below a specific
level.
E240
The communication between the main motor controller and the DC controller is faulty.
0000
There is a fault in the serial communication between
the main controller and the DC controller.
0002
While print is under way, there is no appropriate
response from the DC controller within a specific
period of time.
E243
The control panel is faulty.
0000
There is a fault in the communication between the
controller and the control panel.
E248
The EEPROM on the reader controller PCB is faulty.
0000
The ID stored in EEPROM (read when the main
power is turned on) and the ID stored in the flash
ROM fail to match.
E302
A fault has occurred in relation to shading correction.
0000
A time-out has occurred in
shading operation.
The shading processing does not end 1 sec after it
has started.
0001
A time-out has occurred in gain/
offset correction by the analog
processor.
The gain/offset correction (setting operator) by the
analog processor does not end 1 sec after it has
started.
E315
The image data is faulty.
0001
A time-out condition has occurred in encoding/
decoding processing of image data.
0008
The ASIC (used for compression/expansion
processing) on the image conversion board is faulty.
While encoding is under way, a time-out condition
occurs (i.e., there is no response within 30 sec).
Code
Detail
Description
Timing of detection
Summary of Contents for iR C3200 Series
Page 1: ...Dec 3 2004 Portable Manual iR C3200 Series iR C3220N PRT ...
Page 2: ......
Page 6: ......
Page 10: ......
Page 11: ...Chapter 1 Maintenance and Inspection ...
Page 12: ......
Page 14: ......
Page 22: ...Chapter 1 1 8 ...
Page 23: ...Chapter 2 Standards and Adjustments ...
Page 24: ......
Page 26: ......
Page 40: ...Chapter 2 2 14 ...
Page 41: ...Chapter 3 Error Code ...
Page 42: ......
Page 43: ...Contents Contents 3 1 Error Code Details 3 1 3 1 1 Error Code Details Table 3 1 ...
Page 44: ......
Page 63: ...Chapter 4 User Mode Items ...
Page 64: ......
Page 66: ......
Page 79: ...Chapter 5 Service Mode ...
Page 80: ......
Page 82: ......
Page 121: ...Chapter 6 Outline of Components ...
Page 122: ......
Page 124: ......
Page 134: ...Chapter 6 6 10 F 6 6 PLG1 ELCB1 SP1 H4 H3 H2 H1 H1 H2 LA1 ...
Page 138: ...Chapter 6 6 14 ...
Page 139: ...Chapter 7 System Construction ...
Page 140: ......
Page 142: ......
Page 157: ...Chapter 8 Upgrading ...
Page 158: ......
Page 160: ......
Page 168: ...Chapter 8 8 8 ...
Page 169: ...Dec 3 2004 ...
Page 170: ......