pg. 73
Cause
When the Bk hopper unit was replaced, the claw [A] fixing the unit in place failed to fit into the groove firmly.
As a result, no toner was supplied.
[B] shows the claw that does not fit into the groove, and [C] shows the claw that fits the groove firmly.
Service work
Re-install the Bk hopper unit.