CHAPTER 3 DISASSEMBLY & REASSEMBLY
Figure 3-406
3) Remove the cable
{
1
(FFC) from the
connector.
Figure 3-407
Notes on assembling
Connect the cable and then push in the
reading unit so that the cable returns to
its original folded shape.
4. Reading Holder (Rear)
Note:
This component has the reading glass
and white reference sheet mounted
on it. This component should not be
disassembled unless necessary
because once the component has
been removed, there is a risk of dust
getting inside the reading unit. When
disassembling this component, take
care to prevent dust from getting
inside. Furthermore, take care to
avoid touching the inner side of the
glass and the surface of the lens
array.
1) Remove the reading unit (rear).
2) Place the reading holder
{
1
at the
bottom and unhook the 8 pairs of fitting
parts
{
2
(4x2) using a tool with a thin flat
tip to remove the case
{
3
. Then remove
the CIS unit from the reading holder
{
1
.
Note:
Be careful not to damage the hooks
when unhooking the fitting parts. Once
you have removed the case, the CIS
unit can also be removed, so hold it to
avoid dropping it.
Figure 3-408
Notes on assembling
Push until all of the fitting parts are
securely fastened. There should not be
any raised parts and gaps.
COPYRIGHT
©
CANON ELECTRONICS INC. 2011 CANON DR-C125 FIRST EDITION
3-15