CHAPTER 5 TROUBLESHOOTING
9. Check Device
10. Manual Adjust
This mode displays versions of the
main body firmware and the internal
devices of the main body. The serial
number is also displayed and set.
This mode is used to manually adjust
the scale parameter of images. It can also
be used to manually adjust the registration
position. It is used to correct changes due
to the friction of the roller or to perform fine
adjustment of automatic adjustment values.
This mode should also be executed after
replacing the control PCB that records the
adjustment data.
On the service screen, select [Check
Device] to display the [Check Device]
screen.
Basic screen
On the service screen, click [Manual
Adjust] to display the [Scaling Control]
screen.
Figure 5-226
[MAIN]
Main body firmware
•
•
[DFD SUB]
Ultrasonic sensor
Note:
Version of the main body firmware
can also be confirmed on the user's
driver screen.
Serial number data is saved on the
control PCB. If this PCB is replaced, enter
the serial number shown on the rating
label at the main body and select “Set” on
the right side.
Figure 5-227
COPYRIGHT
©
CANON ELECTRONICS INC. 2011 CANON DR-C125 FIRST EDITION
5-13