C. Duplexing Unit Inlet Motor
Mount Assembly
1. Removing the Duplexing Inlet
Motor Mount Assembly
1) Disconnect the power plug, and remove the
following:
• Rear cover (4 screws)
• Flywheel (3 screws)
• Connector mount
• DC controller PCB (2 screws, all connec-
tors)
• Composite power supply PCB (2 screws,
all connectors)
2) Remove two screws
w
, and disconnect the
connector
e
; then, remove the duplexing unit
inlet motor
q
.
Figure 4-313
D. Set-Back Roller Motor
Assembly
1. Removing the Set-Back Roller
Motor Assembly
1) Disconnect the power plug, and remove the
following:
• Rear cover (4 screws)
• Flywheel (3 screws)
• Connector mount
• DC controller PCB (2 screws, all connec-
tors)
• Composite power supply PCB (2 screws,
all connectors)
2) Remove the three screws
w
, and disconnect
the two connectors
e
; then, remove the set-
back roller motor assembly
q
.
Figure 4-314
2
2
2
3
3
1
1
2
2
3
COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
4–14
4. MECHANICAL SYSTEM