3. OPERATIONS AND TIMING
5. 200PWM Density Auto Correction
•
You must execute this mode in combination with PD density auto correction and 600PWM density auto
correction.
CANCEL
+
OK
*4* FUNCTION 05 – > ( )
200PWM PRINT (START)
WHITE MEASURE (OK)
DENSITY SAMPLING (OK)
DATA SET
A=+xxx, B=+xxx, D=+xxx
xx xx xx xx xx xx xx
xx xx xx xx xx xx xx
MULTI 0
>CASSETTE1 A4 1
CASSETTE 2 A4 1
–
JUMP
Item
200PWM density auto correc-
tion
Description
1) Press ‘200PWM PRIT’ to highlight, and press the
Copy Start key.
• A 15-gradation test pattern will be generated.
2) Place a black sheet of paper (whitest of all used
by the user; no color copy paper allowed) on the
copyboard glass; press ‘WHITE MEASURE’ to
highlight, and press the OK key.
• The scanner makes a single scan.
3) Replace the paper with the test pattern generated
previously; press ‘DENSITY MEAUSRE’ to high-
light, and press the OK key.
4) Check the value of A, B, and D.
Insert
5) If the values are as indicated, press ‘DATA SET’
to highlight, and press the OK key.
Reference
page
Service
handbook
p.2-21.
Printed side down