6.2.
Operation that synchronizes with external trigger Signal input(Raster Scan)
“4-3. raster scan operation”, It can be operated synchronizing with external trigger Signal.
【
The Movement Pattern
】
There are two kinds of movement patterns.
①
(
The raster scan of one coming and going operates whenever the external trigger signal is input.
)
②
(
The raster scan of one way operates whenever the external trigger signal is input.
)
①
and
②
operation pattern can be selected by RS-232C command (Command ID = 23 ‘ Operation
Mode setting ‘)
External Trigger Signal
Raster Scan position
(Current Angle Position)
Angle
Voltage
External Trigger Signal
Raster Scan position
(Current Angle Position)
Angle
Voltage