CANON Digital Galvano Scanner System
KP-1SM GC-251
Users Manual 1.00
73
Parameter ID
22
Parameter
Name
Digital Low-pass Filter Cutoff
Frequency
Data
Cutoff frequency of the digital low-pass filter (Unit: Hz)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the cutoff frequency of the digital low-pass filter.
Related
Command
/Parameter
Parameter ID
23
Parameter
Name
First Analog Notch Filter Central
Frequency
Data
Central frequency of the first analog notch filter (Unit: Hz)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the central frequency of the first analog notch filter.
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter
Parameter ID
24
Parameter
Name
Second Analog Notch Filter Central
Frequency
Data
Central frequency of the second analog notch filter (Unit: Hz)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the central frequency of the second analog notch filter.
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter
Parameter ID
25
Parameter
Name
Third Analog Notch Filter Central
Frequency
Data
Central frequency of the third analog notch filter (Unit: Hz)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the central frequency of the third analog notch filter.
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter