CANON Digital Galvano Scanner System
KP-1SM GC-251
Users Manual 1.00
72
Parameter ID
18
Parameter
Name
First Digital Notch Filter Depth
Data
Depth of the first digital notch filter (Unit: dB)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the depth of the first digital notch filter.
Related
Command
/Parameter
First Digital Notch Filter Central Frequency (Parameter ID = 16)
First Digital Notch Filter Q Value (Parameter ID = 17)
Parameter ID
19
Parameter
Name
Second Digital Notch Filter Central
Frequency
Data
Central frequency of the second digital notch filter (Unit: Hz)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the central frequency of the second digital notch filter.
Related
Command
/Parameter
Second Digital Notch Filter Q Value (Parameter ID = 17)
Second Digital Notch Filter Depth (Parameter ID = 18)
Parameter ID
20
Parameter
Name
Second Digital Notch Filter
Q Value
Data
Second digital notch filter Q value (Unit: ×100)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the Q value of the second digital notch filter.
Set a value multiplied by 100.
Related
Command
/Parameter
Second Digital Notch Filter Central Frequency (Parameter ID = 16)
Second Digital Notch Filter Depth (Parameter ID = 18)
Parameter ID
21
Parameter
Name
Second Digital Notch Filter Depth
Data
Depth of the second digital notch filter (Unit: dB)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the depth of the second digital notch filter.
Related
Command
/Parameter
Second Digital Notch Filter Central Frequency (Parameter ID = 16)
Second Digital Notch Filter Q Value (Parameter ID = 17)