CANON Digital Galvano Scanner System
KP-1SM GC-251
Users Manual 1.00
16
2.7.1 RS-232C command input
RS-232C command input allows the following:
•
Operation
setting
•
Parameter
setting
•
Error
processing
•
Status
check
(For details, see 7, “Commands.”)
If position data send by high-speed serial communication is disabled, RS-232C command input is
enough for the following:
•
Step
movement
•
Raster
scan
(Continuous
oscillation of a certain angle at a fixed frequency)
(Communication specifications)
Wiring Cross
wiring
Communication rate
38400 bps
Data length
8 bits
Stop bit
1
Parity None
Data format
ASCII code
Delimiter code
LF (0x0a) or CR (0x0d)