CANON Digital Galvano Scanner System
KP-1SM GC-251
Users Manual 1.00
42
5.2. Analog
Monitor
Output Selecting
The analog monitor output can be switched to monitor various operation and signal statuses.
This switching can be executed from
[GALILEO]
or
[RS-232C command send]
.
Output contents
Terminal
Power-on
Selection
Signal Description
Signal Level (At Power-on)
A2 (Axis 1)
A6 (Axis 2)
Phase A of Encoder Head 1
Phase A of Encoder Head 2
Phase A of encoder after synthesis
*
Positional deviation signal
1.46 mV / pulse
A3 (Axis 1)
A7 (Axis 2)
Position
0.091 mV / pulse
*
Velocity
0.091 mV / pulse / 10 usec
Coarse
angle
Fine
angle
A4 (Axis 1)
A8 (Axis 2)
Phase B of Encoder Head 1
Phase B of Encoder Head 2
Phase B of encoder after synthesis
*
Target position
0.091 mV / pulse
The signal level differs between signals. The output magnification can be switched individually.