ELURA20 MC A, ELURA10 A
CHAPTER 4. DISASSEMBLING ADJUSTMENT
4-35
2-6-3 C LEVEL Adjustment
TP/TRIG.
VIDEO OUT
M. EQ.
Oscilloscope
SPEC.
C=710 ± 20 [mV]
Procedure)
(1) Referring to the table shown below, carry out C level adjust-
ment.
2-6-4 AGC Initial Value Adjustment
SIGNAL
COLOR BAR
MODE
E-E (ANALOG LINE IN)
SPEC.
Automatic adjustment
Procedure)
(1) Input a color bar signal to the analog line circuit from the pattern generator.
(2) Carry out AGC initial value adjustment according to the table shown below.
Fig.4-25
710 ± 20mV
ST EP
PROCEDURE
MONIT OR
Microcomputer operation
C LEVEL
PG
BK
MD ADDR
DT
ST
1
1) Make the setting shown at right.
6
4
WR
001F
ADJ
Green raster is output.
2) For adjustment, change data properly.
↑
↑
↑
↑
↑
Adjustment is in progress.
3) Press the ST ORE key.
↑
↑
RD
↑
↑
*
Adjustment is completed.
ST EP
PROCEDURE
MONIT OR
Microcomputer operation
AGC INIT IAL
PG
BK
MD ADDR
DT
ST
1
1) Make the setting shown at right.
7
0
WR
**04
--
2) Press the ST ORE key.
↑
↑
↑
↑
↑
+
Automatic adjustment is in progress.
↑
↑
RD
↑
↑
*
Automatic adjustment is completed.