![background image](http://html.mh-extra.com/html/canon/elura10-a/elura10-a_service-manual_58449129.webp)
ELURA20 MC A, ELURA10 A
CHAPTER 4. DISASSEMBLING ADJUSTMENT
4-34
2-6 Recorder Section Adjustment
Preparation)
1)
Except for the tape-path adjustment, carry out adjustment in the product state.
2-6-1 Recorder Setting for Destination
SPEC.
Data writing
Procedure)
(1) Referring to the table shown below, carry out the recorder setting for destination market place.
2-6-2 Y LEVEL Adjustment
TP/TRIG.
VIDEO OUT
M. EQ.
Oscilloscope
SPEC.
Y=980 ± 20 [mV]
Procedure)
(1) Referring to the table shown below, carry out Y level adjustment.
ST EP
PROCEDURE
MONIT OR
Microcomputer operation
RECORDER DEST INAT ION
PG
BK
MD ADDR
DT
ST
1
1) Make the setting shown at right.
6
5
WR
**00
01
3) Press the ST ORE key.
↑
↑
RD
↑
↑
*
High address "01" is set up.
2
1) Make the setting shown at right.
6
4
WR
0112
F0
Function Select bit for USA
(For USA model)
2) Make the setting shown at right
6
4
WR
0112
F1
Function Select bit for JPN
(For Japan model)
3) Press the ST ORE key.
↑
↑
RD
↑
F0orF1
*
T he recorder setting for destination
market place is completed.
Fig.4-24
980 ± 20mV
ST EP
PROCEDURE
MONIT OR
Microcomputer operation
Y LEVEL
PG
BK
MD ADDR
DT
ST
1
1) Make the setting shown at right.
6
4
WR
001E
ADJ
White raster is output.
2) For adjustment, change data properly.
↑
↑
↑
↑
"ADJ"
Adjustment is in progress.
3) Press the ST ORE key.
↑
↑
RD
↑
↑
*
Adjustment is completed.