COPYRIGHT © 1999 CANON INC.
CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
5-7
CHAPTER 5 TROUBLESHOOTING
Figure 5-113
Screw
Upper cover
Registration roller
mounting plate
If A>0, slide the mounting plate down.
If B>0, slide the mounting plate up.
Figure 5-114
Screw
ADF controller cover
2) Open the upper cover, and loosen the fixing
screw on the registration roller mounting
plate; then, adjust the mounting angle of the
registration roller by sliding mounting plate up
or down.
3) After making adjustments, tighten the fixing
screw on the registration roller mounting
plate.
4) Put the DIP switch (SW1) on the ADF con-
troller PCB back to its original state, and at-
tach the ADF controller cover.
b. Pickup from the Manual feeder Tray
1) Remove the screw, and detach the ADF
controller cover.
2) Set the DIP switch (SW1) on the ADF con-
troller PCB as shown in Figure 5-115.
Figure 5-115