CHAPTER 5 TROUBLESHOOTING
5-44
COPYRIGHT © 1999 CANON INC.
CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Switch
SW3
SW4
LED2
1-X1-X2-Y1-Y2
2-X1-X2-Y1-Y2
3-X1-X2-Y1-Y2
Description
Most recent
jam
Second
most recent
jam
Third most
recent jam
4) Operate the push switches (SW3 and SW4)
to switch the LED2 indication, thereby
checking the jam history.
LED2 will flash five times to indicate the
nature of the jam.
X1, X2 : Jam code.
Y1, Y2 : Not used.
Table 5-122
5) After making adjustments, press the push
switch (SW2) on the ADF controller PCB.
4. Software Version
1) Remove the screw, and detach the ADF
controller cover.
2) Set the DIP switch (SW1) on the ADF con-
troller as shown in Figure 5-188.
3) Press the push switch (SW2) on the ADF
controller PCB.
LED2 will flash four times to indicate the
software version.
EX.
In the case of version 3.01,
4) Press the push switch (SW2) on the ADF
controller PCB to find out the version of the
software.