CHAPTER 5 TROUBLESHOOTING
Figure 5-101
Lower front cover
Screw
Screw
Figure 5-102
(left)
(right)
[3]
[4]
[5]
[5]
[3]
[4] [5]
[5]
I . STANDARDS AND
ADJUSTMENTS
A. Basic Adjustments
The machine's basic adjustments include the
following, which must be performed in sequence:
[1] Adjusting the height of the ADF
[2] Adjusting the orientation of the ADF
[3] Removing the skew.
[4] Adjusting the horizontal registration
[5] Adjusting the original stop position
1.
Adjusting the Height of the ADF
1) Remove the two screws, and detach the
lower front cover.
2) With the ADF closed, make adjustments by
loosening the two fixing screws [5] of the
magnet catch [4] so that both rubber feet [3]
are in contact.
3) After making adjustments, tighten the fixing
screws of the magnet catch, and attach the
front cover.