8
8
8-45
8-45
Service Mode > TESTMODE > FAX > FACULTY
Service Mode > TESTMODE > FAX > FACULTY
TESTMODE > FAX > MODEM
M82 M85
V34G3TX
V.34 G3 signal transmission test
▲
▲
Details
To test whether the specified V.34 G3 signal is
transmitted.
By closing or opening the DC circuit in accordance
with the setting value, the specific G3 signal pattern
is transmitted at the specified transmission speed and
modulation speed by the G3 signal transmission function
(V.34) of the modem.
Check this with the speaker.
A setting value other than 0 is indicated as a 3-digit
integer (1st digit: modulation speed, last 2 digits:
transmission speed). A value other than the specified
numerical value is invalid.
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 614
0: OFF
• First digit (Modulation speed/baud rate)
1: 2400 baud, 2: 2743 baud, 3: 2800 baud, 4: 3000
baud, 5: 3200 baud, 6: 3429 baud
• Last 2 digits (Transmission speed)
01: 2400 bps, 02: 4800 bps, 03: 7200 bps, 04: 9600
bps, 05: 12000 bps, 06: 14400 bps, 07: 16800 bps, 08:
19200 bps, 09: 21600 bps, 10: 24000 bps, 11: 26400
bps, 12: 28800 bps, 13: 31200 bps, 14: 33600 bps
Default value
0
■
FACULTY
TESTMODE > PRINT
M82 M85
G34800TX
G3 4800 bps signal transmission test
▲
▲
Details
To test whether the G3 signal is transmitted at 4800 bps.
By closing or opening the DC circuit, the specific G3
signal pattern is transmitted at 4800 bps by the G3 signal
transmission function.
Check this with the speaker.
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
T-8-44
TESTMODE > PRINT
M82 M85
DETECT1
Ring detection
▲
▲
Details
To check the ON/OFF state of CI, FC, and hook from the
line.
The detection results are displayed on the console
(UART).
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
CI (Calling Identification): Ring signal
UART (Universal Asynchronous Receiver Transmitter):
Console
DETECT2
Calling tone detection test 1
▲
▲
Details
To check calling tone signal and FED.
Set the CML relay to ON and detect the calling tone.
The detection results are displayed on the console
(UART).
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
CML (Connect Modem to Line) relay: Relay installed at
the NCU (Network Control Unit) Board to switch between
the telephone and fax.
DETECT3
Calling tone detection test 2
▲
▲
Details
To check calling tone signal and FED.
Set the CML relay to OFF and detect the calling tone.
The detection results are displayed on the console
(UART).
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
CML (Connect Modem to Line) relay: Relay installed at
the NCU (Network Control Unit) Board to switch between
the telephone and fax.
T-8-45
Summary of Contents for Color imageCLASS MF8280Cw
Page 317: ...5 5 Adjustment Adjustment Overview Adjustment at Parts Replacement ...
Page 340: ...7 7 Error codes Error codes Overview Error Codes Jam Code ...
Page 349: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 394: ... Special Tools Solvents and Oils General Circuit Diagram Backup Data Appendex ...