Appendix B ‒ Vibrating Wire Measurement Configuration
MLTDR-W-50S User's Guide
67
For stations that include a multiplexer, the multiplexer is connected directly to the CR6. When the multiplexer is
configured, its specific model is selected as the
Model
, and
Vibrating Wire
as
Gage Type
.
(The Configure Multiplexers form, configured for monitoring Vibrating Wire gages)
Press
Edit Channels
to configure the channels. Note that the Channel number shown on the left of the
Channel Configuration Multiplexer form corresponds to the order the sensors are wired to the multiplexer.
When configuring the Channels,
Vibrating Wire
is the only option for
Gage Type
in the
Measurements
group.
Example for Channel 1 is shown, using the same example VW piezometer as was used in the previous
section.
(Typical settings for a VW piezometer connected to a multiplexer)