Model

Instruction
Manual

Humidity/Temperature 

Datalogger

SD-3007 

reedinstruments

www

com

Summary of Contents for SD-3007

Page 1: ...Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 Model Instruction Manual Humidity Temperature Datalogger SD 3007 reedinstruments www com...

Page 2: ...Temperature measurement 7 Dew Point measurment 7 Wet Bulb measurement 7 Data Hold 8 Data Record Max Min reading 8 Backlight ON OFF 9 Datalogger 9 Auto Datalogger 9 10 Manual Datalogger 10 Checking the...

Page 3: ...D card into the computer and it downloads directly to EXCEL SD card capacity 1 GB to 16 GB Easy to read LCD with backlight Auto power off or manual power off Data hold record max and min reading High...

Page 4: ...2 F Operating Humidity Less than 85 R H Power Supply UM3 AA 1 5 V x 6 batteries Weight 515g 1 13lb Dimensions 177 x 68 x 45mm 7 0 x 2 7 x 1 9 Includes Humidity Temp probe Optional accessories 2G SD Ca...

Page 5: ...1 6 C 50 0 C 6 9 F 122 0 F R solution 0 1 Type K J thermometer Sensor Type R solution Range Accuracy Type K 0 1 C 50 0 to 1300 0 C 0 4 0 5 C 50 1 to 100 0 C 0 4 1 C 0 1 F 58 0 to 2372 0 F 0 4 1 F 58 1...

Page 6: ...ed 10 100 100 5 Instrument Description 1 Display 2 Power ESC Backlight Button 3 Hold Button Function Button Next Button 4 REC Button Enter Button 5 SET Button Up Button Time Check Button 6 Logger Butt...

Page 7: ...rmometer measurement Release the Function Button to choose the displayed function Humidity Temperature measurement 1 1 When the meter is off plug the Probe into the Probe Input Socket then power on th...

Page 8: ...Button once and the mea sured value will hold on the screen and a HOLD symbol will appear Press the Hold Button once again will release the data hold function Data Record Max Min reading The data rec...

Page 9: ...rst time the meter is used you need to adjust the clock See Advanced Settings section of this manual for instruc tions 4 Now you need to set the decimal format The numerical data struc ture downloaded...

Page 10: ...time the measuring data along the time infor mation will be saved in memory The lower Display will show the Position record number which is saved as well 2 To Change the Position Number press the Down...

Page 11: ...3 The folder HTA01 can hold 99 XLS files When that number has been reached the meter will then will generate a new folder with a subsequent number for example HTA02 Max number of HTA folders is 10 Dat...

Page 12: ...Auto power OFF management bEEP Set beeper sound ON OFF tYPE Select the Thermometer to Type K or Type J t CF Select the temperature unit to C or F SP t Set sampling time Hour Minute Second Sd F SD mem...

Page 13: ...agement 1 When the lower display shows PoFF use the Up or Down But tons to select the value yES Enable Auto Power Off or no Disable Auto Power Off 2 After selecting yES or no press the Enter Button to...

Page 14: ...ault To exit Advanced Settings press the Esc Button Set sampling time 1 When the lower display shows SP t use the Up or Down Buttons to adjust the value to either 0 1 2 5 10 30 60 120 300 600 1800 or...

Page 15: ...or output is a 16 digit data stream which can be utilized to the user s specific application An USB RS232 lead with the following connection will be required to link the instrument with the PC serial...

Page 16: ...utton does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstruments com for more information Battery Replacement 1 When the left corner of LCD display sh...

Page 17: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Page 18: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Page 19: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Page 20: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Reviews: