Section 4
‒ MultiLogger Configuration
34
MLTDR-W-50S User's Guide
Scroll to the bottom of the Location list (should be location 47), check
Store Location
, click in the
Label
field
and enter the label "TDR_Channel".
Note - Be sure to check Store Location prior to entering anything in the Label field. This sets Store Location for all
positions in the array. If Store Location is not first checked, the entire array must be rebuilt. Delete the Label of the first
location in the array to delete the rest, then rebuild.
(Configuring the location for the TDR channel number)
The location should be inserted, and the Location list will increment by one.
Advance to the next Location (should be location 48), check
Store Location
, click in the
Label
field and enter
the Label “TDR_Waveform(1015)” if using a
TDR200
, or "TDR_Waveform(1012)" if using a
TDR1000
.
(Configuring the location for the TDR waveforms using a TDR200)
Note
‒ The number of locations to be assigned depends on the number of points to be used for the TDR cable
signature capture. Add 15 to the number of points for a TDR200, add 12 to the number of points for a TDR100, the
example above shows
signatures will have 1000 points.
Once all locations have been configured for storage, press
Accept
to return to the Logger form.