Subsection XX (FRAME)
PROCEDURES
FRAME
Frame Inspection
Check frame for bending, cracks, weld damages
or any other damage. Replace frame as neces-
sary.
Frame Welding
No welding should be done on frame except if
mentioned or required on an approved BRP Bul-
letin.
Frame Insert Replacement
To install a new blind threaded insert, use the fol-
lowing tool:
BLIND THREADED INSERT INSTALLER
(P/N MODEL 9600)
from Textron. See their web
site at:
www.textronfasteningsystems.com
.
tmr2011-039-004
After insert installation, ensure insert can hold the
torque applied to the screw it retains and measure
the compressed length of the frame insert. Oth-
erwise, install a new insert.
INSERT
COMPRESSED
LENGTH
Insert for M6 bolt
9 mm ± 0.5 mm
(.354 in ± .02 in)
Insert for M8 bolt
11.5 mm ± 0.5 mm
(.453 in ± .02 in)
vmr2012-044-002_a
INSERT FOR M6 BOLT SHOWN
A. 9 mm ± 0.5 mm (.354 in ± .02 in)
Frame Replacement
Blind threaded inserts are not installed on replace-
ment frames. Make sure to order enough inserts
when replacing frame. Refer to
ELECTRONIC
PARTS CATALOG
.
vmr2013-047
3