Subsection 11 (CONTINUOUSLY VARIABLE TRANSMISSION (CVT)(570/850))
vmr2006-021-024_a
A. Centrifugal lever pivot bolt bore diameter
CENTRIFUGAL LEVER PIVOT BOLT BORE
DIAMETER
NEW
6.113 mm to 6.171 mm
(.241 in to .243 in)
SERVICE LIMIT
6.300 mm (.248 in)
Measure bushing diameters of sliding sheave.
REQUIRED TOOL
Dial bore gauge
MEASURING POINT
At least 5 mm (1/4 in) from bushing edge
R610tran14A
A
1
1. Bushing on fixed sheave side
A. Bore diameter of bushing
SLIDING SHEAVE LARGE BUSHING
NEW
55.000 mm to 55.040 mm
(2.165 in to 2.167 in)
SERVICE LIMIT
55.200 mm (2.173 in)
R610tran11A
A
1
1. Bushing on governor cup side
A. Bore diameter of bushing
SLIDING SHEAVE SMALL BUSHING
NEW
32.000 mm to 32.040 mm
(1.26 in to 1.261 in)
SERVICE LIMIT
32.200 mm (1.268 in)
Replace sliding sheave if one of the bushings is
out of specification. Visually inspect coatings for
wear.
Fixed Sheave
Check fixed sheave contact surface to the gover-
nor cup for scratches or other damages. If dam-
aged, replace fixed sheave.
Vmr2012-018-010_a
1. Visually check here
vmr2016-404
11