Subsection 01 (POWER DISTRIBUTION AND GROUNDS)
vmr2016-132-003_a
PRE-ASSEMBLED REPLACEMENT FUSE LINK
1. Insulated fuse link wire
2. Butt end terminal
3. Terminal factory crimped on fuse link
4. Crimp here when installing in circuit
5. Solder ring
1. Disconnect the battery.
2. Cut the circuit wiring as close as possible to the
fuse link terminals.
3. Remove 8 mm (5/16 in) of insulator from the
ends of the circuit wiring.
4. Insert the circuit wire end in the link terminal
making sure the wire end bottoms out in the
center of the terminal.
5. Crimp the terminal on the bare wire.
6. Using a heat gun, carefully heat the link ter-
minal until the solder ring has melted into the
wiring, and the terminal insulator has shrunk
tightly around the terminals and wire insulators.
7. Reconnect the battery.
4
vmr2016-132