![Campbell CCFC Product Manual Download Page 128](http://html1.mh-extra.com/html/campbell/ccfc/ccfc_product-manual_489121128.webp)
3. Go to Settings Editor > ComPort Settings
4. Turn off the RS-485 Beacon interval by setting it to 0
5. Set the Verify interval to a large number (for example, 65000)
21. Remote photo retrieval
Once the camera has transferred a photo or video to a data logger, existing
LoggerNet
communications can be used to remotely retrieve the photos and video from the data logger
memory.
The CCFC web interface also has permanent links for downloading the most recently captured
photos or video files saved to the camera memory (see
(p. 32)).
21.1 LoggerNet file retrieval
LoggerNet
(version 4.0 or newer) includes the File Retrieval setup that facilitates the photo and
video file retrieval from PakBus® data loggers (CR6, CR3000, CR1000X, CR800 series, CR300
series, and CR1000). The File Retrieval tab is located in the Setup Screen as part of the data logger
configuration. Once configured, File Retrieval is used to retrieve photos and video from a data
logger.
FIGURE 21-1. File Retrieval Setup Screen
CCFC Field Camera
122