background image

Portable Air Compressors

2

 1.  Read instruction manuals for 

each component carefully, 
before attempting to assemble, 
disassemble or operate your 
particular system.

 2.  Wear safety glasses and 

use hearing protection 
when operating the 
pump or unit.

 3.  Do not stand on or use the pump or 

unit as a handhold.

 4.  Do not exceed pressure rating of 

any component in system.

 5.  Protect material lines and air lines 

from damage or puncture. Keep 
hose and power cable away from 
sharp objects, chemical spills, oil, 
solvents, and wet floors.

 6.  Never point a spray gun at oneself 

or any other person. Accidental 
discharge may result in serious injury.

 7.  Check hoses for weak or worn 

condition, before each use, making 
certain all connections are secure; 
do not use if deficiency is found. 
Notify an authorized service facility 
for examination or repair.

 

Do not run 

  unattended. leaving 

compressor in oN position may allow it to 
turn on inadvertently. To prevent this and 
possible damage from power surge, turn 
to oFF position after each use.

 8.  Release all pressures within system 

slowly; dust and debris may be 
harmful.

 

Keep 

  fingers 

away from a running 
compressor; fast moving 
and hot parts will cause 
injury and/or burns.
 

 Disconnect power  

   and depressurize 

system before servicing air compressor! 

 9.  Follow all local electrical and safety 

codes, as well as the National Electrical 
Code (NEC) and the Occupational 
Safety and Health Act (OSHA).

 10. Wiring and fuses should follow 

electrical codes, current capacity, and 
be properly grounded.

 11. Electric motors must be securely and 

adequately grounded. See grounding 
instructions and extension cord 
information, in this manual.

12. Always disconnect power source 

before working on or near a motor, or 
its connected load. If power disconnect 
point is out-of-sight, lock it in the 
open position and tag to prevent 
unexpected application of power.

13. Guard all moving parts; keep 

visitors away. Never allow children 
in work area.

14. Use only a properly grounded 

outlet that will accept a three 
pronged plug, and wear shoes to 
prevent shock hazards.

 

Be

  careful 

when touching exterior of 
operating motor; it may be 
hot enough to cause injury. 
compressor parts may be hot 
even if the unit is stopped.

15. Protect power cable from coming in 

contact with sharp objects.

16. Clean electrical or electronic 

equipment with an approved cleaning 
agent, such as dry, nonflammable 
cleaning solvent.

                               Motors, 

  electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair the 
unit near a flammable gas or vapor. 
Never store flammable liquids or gases 
in the vicinity of the compressor.

17. To reduce fire hazard, 

keep engine/motor 
exterior free of oil, 
solvent, or grease.

18. To avoid spontaneous combustion, 

discard waste rags into approved 
metal waste cans.

19. NEVER reset safety valve or pressure 

switch. Keep safety valve free from 
paint and other accumulations. This 
provides safety against over pressure.

 

Never remove or 

  attempt to adjust 

safety valve. Keep safety valve free 
from paint and other accumulations.

20. Do regular maintenance; keep all 

nuts, bolts, and screws tight, to be 
sure equipment is in safe working 
condition .

21. Keep cleaning rags and other 

flammable waste materials in a tightly 
closed metal container and dispose of 
later in the proper fashion.

22. Drain tanks of moisture after each 

day’s use. If unit will not be used for 
a while, it is best to leave drain cock 
open until such time as it is to be used. 
This will allow moisture to completely 
drain out and help prevent corrosion 
of inside of tank.

23. Inspect tank yearly for rust, pin holes 

or any other imperfections that could 
cause it to become unsafe. NEVER 
weld or drill holes in air tank.

 

Never attempt 

  to repair or modify a 

tank! welding, drilling or any other 
modification will weaken the tank resulting 
in damage from rupture or explosion. 
Always replace worn or damaged tanks.
 

Drain liquid from 

  tank daily.

SPRAYING PRECAUTIONS

 

Do not spray 

  flammable materials 

in vicinity of open flame or near ignition 
sources including the compressor unit.

24. Spray in a well ventilated area, to keep 

fumes from collecting and causing 
health and fire hazards.

25. Do not spray in vicinity of open flames 

or other places where a spark can 
cause ignition. Do not smoke when 
spraying paint, insecticides, or other 
flammable substances.

26. Use a respirator when spraying.
27. Do not direct paint or other sprayed 

material at the compressor. Locate 
compressor as far away from 
the spraying area as possible to 
minimize overspray accumulation 
on the compressor.

28. When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.

29. Do not smoke when spraying paint, 

insecticides, or other flammable 
substances.

30. Use a face mask/ 

respirator when 
spraying and spray in a 
well ventilated area to 
prevent health and fire hazards.

31. Household use only.
32. To reduce the risk of electrical shock, 

do not expose to rain. Store indoors.

www.chpower.com

General Safety 

(Cont.)

 

Summary of Contents for HM7000

Page 1: ...r to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA DIS...

Page 2: ...and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair the unit near a flammable gas or vapor Never store flammable liquids or gases in the vicinity...

Page 3: ...to an outlet but if this is not possible an extension cord may be used It should be selected using the extension cord chart on page 3 as a guide 4 To avoid loss of power and overheating it is better t...

Page 4: ...es the maximum preset pressure In the Off position the compressor will not operate This switch should be in the Off position when connecting or disconnecting the power cord from the electrical outlet...

Page 5: ...compressor for any visible problems especially check air filter to be sure it is clean 2 Pull ring on safety valve and allow it to snap back to normal position Figure 6 Safety valve must be replaced...

Page 6: ...www chpower com Notes Portable Air Compressors...

Page 7: ...2 Check gauge chart under Operation for proper gauge wire and cord length 3 Replace motor 4 Replace or repair 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances from c...

Page 8: ...ited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any...

Page 9: ...pour la respiration Grade D d crit dans le Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 et ou Canadian Standards Associations CSA D N GATION DES GARANTIES Si le...

Page 10: ...de ne pas toucher l xt rieur du moteur car il peut tre assez chaud pour causer des blessures 15 Prot ger le c ble lectrique contre les objets pointus 16 Nettoyer l quipement lectrique ou lectronique...

Page 11: ...prise d air du compresseur pr s de la vapeur un jet pulv ris de peinture endroits de d capage au sable ou autre sources de contamination Le d bris endommagera le moteur R serv l utilisation r sidentie...

Page 12: ...cordon et son classement en amp res sur la plaque indicatrice Si vous avez des doutes utilisez le calibre plus lourd REMARQUE Le plus petit le num ro du calibre le plus lourd le cordon 4 Ce produit es...

Page 13: ...du r servoir en utilisant un mandrin de pneu un outil etc alors le compresseur red marrera automatiquement sa pression pr tablie de coupure Lorsqu un outil est utilis continuellement le compresseur pa...

Page 14: ...compresseur est de type sans huile et n exige pas de graissage PROTECTEUR DE SURCHARGE THERMIQUE Fermer le pressostat ou d brancher le compresseur pendant 20 minutes et le laisser refroidir L apparei...

Page 15: ...our le calibre de fil et la taille de cordon prolongateur corrects 3 Remplacer le moteur 4 Remplacer ou r parer 1 V rifier le type de fusible utiliser un fusible retardement D brancher les autres appa...

Page 16: ...est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...G 7 1 1966 de la Asociaci n de Aire Comprimido Igualmente deber cumplir los requisitos establecidos por el Articulo 29 CFR 1910 134 de la Organizaci n norteamericana OSHA y o la Canadian Standards Ass...

Page 18: ...s aislantes para evitar electrocutamiento Tenga cuidado al tocar la parte externa del motor encendido ste podr a estar lmuy caliente y ocasionarle heridas 15 Evite que el cord n el ctrico tenga contac...

Page 19: ...de los tornillos 3 Enrosque el tornillo en el agujero hasta que quede ajustado Instalaci n Colocaci n Es de suma importancia instalar el compresor en un llugar limpio y bien ventilado donde la tempera...

Page 20: ...el rea de trabajo 1 Use s lo cordones de extensi n con 3 cables que tengan 3 terminales para conexi n a tierra y tomacorrientes con 3 orificios adecuados para conectar este producto 2 Cerci rese de qu...

Page 21: ...umedad del tanque diariamente para evitar que se oxide Drene la humedad del tanque abriendo la v lvula de drenaje que se encuentra debajo o en uno de los lados del tanque Antes de arrancarlo por prime...

Page 22: ...ie el elemento o todo el filtro Lubricacion Este compresor no requiere lubricaci n protector termico Apague el interruptor de presi n o desconecte el compresor por 20 minutos y d jelo enfriar Reinicia...

Page 23: ...cord n de extensi n adecuado vea la secci n CORDONES DE EXTENSION p gina 15 2 Est conectado Chequee el fusible cortacircuito o protector de sobrecarga del motorfuse breaker or motor overload 3 Reempl...

Page 24: ...arant a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado...