Operation and maintenance instructions
Series PRE proportional pressure regulator
IO-Link version
5000030186
Ver. 03
28
▪
Device parametrization parameters
Address
Parameter
Access
(RO, WO
o RW)
Dimension
(byte)
Description
0x103
(259)
Unit of
measurement
(regulator)
RW
1
Unit of measurement of the
regulator
0x104
(260)
Minimum target
pressure
RO
2
Minimum target pressure accepted
by the regulator
0x105
(261)
Maximum target
pressure
RO
2
Maximum target pressure accepted
by the regulator
0x106
(262)
Pressure switch
control
RW
1
Enables the pressure switch control
function
0x107
(263)
Pressure window
control
RW
1
Enables the pressure window
control function
0x108
(264)
Lower limit switch
control
RW
2
Lower threshold of the pressure
switch control function
0x109
(265)
Upper limit switch
control
RW
2
Upper threshold of the pressure
switch control function
0x10A
(266)
Lower limit window
control
RW
2
Lower threshold of the window
control function
0x10B
(267)
Upper limit window
control
RW
2
Upper threshold of the window
control function
0x10C
(268)
Pressure regulation
check mode
RW
1
Sets the generated error type in
case the pressure falls out of the
target value
0x10D
(269)
Pid mode
RW
1
Sets the PID gains of the regulator
0x10E
(270)
Pressure regulation
check
RW
1
Allows to check the regulated
pressure
0x10F
(271)
Pressure regulation
check timeout
RW
2
Sets the time to achieve the
regulated pressure