Operation and maintenance instructions
Series PRE proportional pressure regulator
IO-Link version
5000030186
Ver. 03
22
o
Connection
: indicates if the device is transmitting or, more precisely, if the UVIX is
receiving data from it. The indication is given by the color of the dot that turns green
if the device is connected or red if it is not connected.
o
Under the device picture the “Configuration” command
is located. Via this command
it is possible to open the configuration window of the selected device
11.3.
Details
This section is divided into 3 sub-sections and lists specific information about selected device.
VARIABLES
This sub-section lists all variables sent from the device to UVIX, including those related to Coil
Vision if the device is equipped with advanced diagnostics.
•
Hardware Version: device hardware version.
•
Product Code: commercial code of the device.
•
Command signal: reference signal used by the device.
•
Temperature: device temperature value.
•
Supply Voltage: power supply value.
•
Set Pressure: target pressure.
•
Regulated Pressure: regulated pressure value.
•
Charge coil cycles: number of cycle of charge coil.
•
Exhaust coil cycles: number of cycles of exhaust coil.
•
Charge coil health status: health status of charge coil.
•
Exhaust coil health status: health status of exhaust coil.
•
Charge coil work time: total working time for charge coil.
•
Exhaust coil work time: total working time for exhaust coil.
ALARM
This
section
lists
all
the
possible
warnings
and
alarms,
for each of them the status is specified and, if active, the date on which the error occurred.