Operation and maintenance instructions
Series PRE proportional pressure regulator
IO-Link version
5000030186
Ver. 03
29
0x117
(279)
Protection timeout
RW
1
Sets the inactivity time when a
PRESSURE OUT OF RANGE warning
occours.
0x118
(280)
Pressure failsafe
RW
1
Set the regulator behavior if the
communication with master is
interrupted.
▪
Device diagnostic parameters
Address
Parameter
Access
(RO,
WO o
RW)
Dimension
(byte)
Description
0x110
(272)
Health status
charge coil
RO
1
Health status as a percentage of the
charge coil
0x111
(273)
Health status
exhaust coil
RO
1
Health status as a percentage of the
exhaust coil
0x112
(274)
Cycles charge
coil
RO
4
Indicates the number of cycles
performed by the charge coil
0x113
(275)
Cycles exhaust
coil
RO
4
Indicates the number of cycles
performed by the exhaust coil
0x114
(276)
Total work time
charge coil
RO
4
Total time that the charge coil has
been on
0x115
(277)
Total work time
exhaust coil
RO
4
Total time that the exhaust coil has
been on
0x116
(278)
Temperature
RO
2
Indicates the internal temperature
of the regulator
0x0024
(36)
Device status
RO
1
Indicates the device status
0x0025
(37)
Detailed Device
Status
RO
192 (list of 64
elements, 3 byte
every element)
For every element, first byte indicate
the eventQualifier and the others
two bytes indicate the event code
(refer to the dedicated chapter)
The various parameters are described in detail below