Electro-pneumatic Regulator ER100
Instruction Manual
rev. 2.0
page 21 / 38
4.2.
Function List
Display
Name
Displayed data (in run mode)
Setting (in setting mode)
Pressure
display
The pressure on the secondary side
(outgoing pressure) is shown through the
three-digit number LED display.
Unit
:
Bar
1digit = 0,01Bar
Display F1
Input signal
selection
Shows the selected input signal type.
* When preset memory mode is
selected (the 8 setting points), the
currently selected preset number and
target value are displayed.
<In case of analog type>
The analog input, preset memory
input or direct memory input can be
selected.
In case of the preset or direct memory
input, enter the setting in this mode.
<In case of parallel type>
The parallel input or direct memory
input can be selected.
In case of the direct memory input,
enter the target value in this mode.
Display F2
Zero/span
adjustment
With “F2” it is possible to activate the
Zero/Span adjustment mode. When
activating this function, “F2.” is displayed,
followed by the adjusted zero point setting
(L) and the adjusted span point setting
(H).
The factory setting is set to the full
scale which means that the display
will be shown, i.e it is not activated.
Use in the full scale or adjust the zero
and span settings upon selection.
If zero/span adjustment is selected,
adjust the values in this mode to the
desired values.
Display F3
Auto power-off
With “F3” it is possible to activate the
energy saving function. If activated, the
LED display is automatically switched
OFF after approx. 1 minute. The display is
switched ON again simply by touching
any of the keys.
* The factory setting is set to
de-activated and on the display
will be shown.
Select whether the auto power-off
function activated or not.
Note: The interval to auto power-off is
about one minute. The interval
may not be changed.
Display F4
Switch output
※
Function
“F4”
available for
regulator
with switch
output only.
With “F4” it is possible to
activate/de-activate the Switch Output
function. When activating this function,
the switching mode and limits have to be
selected. There are two modes available.
If “mode 1” is selected, “F4.1” is
displayed, followed by the “negative” limit
setting point (L) and “positive” limit setting
point (H) in one sequence.
If “mode 2” is selected is selected, “F4.2”
is displayed, followed by the lower limit
setting point (L) and the upper limit setting
point (H) in one sequence.
※
The factory setting is set to
de-activated and on the display
will be shown.
Select whether the switch output
function should be activated or not.
If the function is activated, you can
select either “mode 1” or “mode 2.”
Enter the desired positive and negative
limits (for mode 1) or the upper and
lower limits (for mode 2).
Note: The hysteresis cannot be
adjusted.
Display F5
Proportional
value change
* only for
model
ER104-1
Proportional value change and the setting level
can be checked. In case of “proportional value
increase”, “F5.H” is displayed. In case of
“proportional value decrease” , “F5.L” and the
setting level are displayed alternately.
* In the factory shipmentstate, the standard
value (- -) is specified.
Operate in the standard value state, or
operate with a desired proportional value
upon selection.
Only when “proportional value decrease” is
selected, the desired proportional value level
can be specified in this mode (in 10 steps).