Electro-pneumatic Regulator ER100
Instruction Manual
rev. 2.0
page 23 / 38
4.3.2.
Zero- and Span Adjustment
Control and activation of the zero/span adjustment with the respective settings.
Note:
This function is not available if the preset memory input or direct memory input
function is selected in the “F1 mode.”
If adjustment
is not activated
:
If adjustment
is activated:
Setting (%)
Zero point adjustment
Setting (%)
Span point adjustment
If adjustment is not activated
100%
C
ontr
o
l pr
es
su
re
0% 100%
Input signal
If adjustment is activated
100%
C
ontr
o
l pr
es
su
re
0%
100%
Input signal
Zero point (L) setting
range: 0 to 50%
Span point (H) setting
range: 100 to 10%
4.3.3.
LED - Auto Power-Off
Control and activation of the LED auto power-off function with “F3” .
If the function is not activated:
If the function is activated:
4.3.4.
Switch Output Function”F4”
Control and activation/de-activation of the switch output function.
Note:
This function is not available for the analog output specification.
< Mode 1 >
L
(Negative
admissible limit)
Input signal setting
H
(Positive
admissible limit)
ON
OFF
Output
< Mode 2 >
L
(Lower limit)
H
(Upper limit)
ON
OFF
Output