23
Contents
1. Read first and then... ................................................ 23
2. Scope of supply ........................................................ 23
3. Specification and ordering information ..................... 23
4. Brief description ........................................................ 24
5. Technical data ........................................................... 24
6. Overview of the parts ................................................ 26
7. Exchanging frontplates ............................................. 26
8. Withdrawing and inserting the device ....................... 26
9. Mounting ................................................................... 26
10. Electrical connections ............................................... 27
11. Configuration ............................................................ 31
12. Commissioning ......................................................... 31
13. Releasing the power pack ........................................ 32
14. Dimensional drawings ............................................... 32
1. Read first and then …
The proper and safe operation of the device
assumes that the Operating Instructions are
read
and the safety warnings given in the
various Sections
9. Mounting
10. Electrical connections
12. Commissioning
are
observed
.
The device should only be handled by appropriately
trained personnel who are familiar with it and authorised
to work in electrical installations.
Power pack (1)
2
withdrawing handle (2)
(for withdrawing the device from
its housing)
2
frontplates (3)
(for notes)
1
Ex approval (4)
(only for Ex version devices)
1
Operating Instructions (5)
, in three languages: German,
French, English
(2)
(1)
(5)
(4)
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
T41 56 618 21 11
T41 56 618 24 58
Telex 827 901 cbm ch
Camille Bauer AG
B 811 B d-f-e
999 469
4.96
Betriebsanleitung
Speiseferät SINEAX B 811
Mode d’emploi
Source d’alimentation SINEAX B 811
Operating Instructions
Power pack SINEAX B 811
(3)
GOSSEN
METRA
W
ATT
CAM
ILLE BAUER
SINEAX
B 811
ON
SINEAX
B 811
ON
GOSSEN
METRA
W
ATT
CAM
ILLE BAUER
2. Scope of supply
(Fig. 1)
Operating Instructions
Power pack SINEAX B 811
3. Specification and ordering information
Order Code
811 –
1. Mechanical design
Housing S17
1
2. Version/Power supply H
(nominal voltage U
N
)
Standard / 24… 60 V DC/AC
1
Standard / 85…230 V DC/AC
2
[EEx ia] IIC
3
24…60 V DC/AC
MSK intrinsically safe
[EEx ia] IIC
4
85…110 V DC/85…230 V AC
MSK intrinsically safe
3. Output signals
measuring outputs A1aund A12
0… 5 V, R
ext
≥
250
Ω
1
1… 5 V, R
ext
≥
250
Ω
2
0…10 V, R
ext
≥
500
Ω
3
2…10 V, R
ext
≥
500
Ω
4
Non-standard 0…> 5 to 0…15 V
8
Live zero > (1…5) to 3…15 V
9
0…20 mA, R
ext
≤
750
Ω
(500
Ω
)
A
4…20 mA, R
ext
≤
750
Ω
(500
Ω
)
B
Non-standard 0…1 to 0…< 20 mA
Y
Live zero 0.2…1 to < (4…20) mA
Z
4. FSK (Field communications protocol)
Not designed for communications protocol
0
Designed for FSK communication
1
at field output A12
Designed for FSK communication
2
at measuring output A1
5. Input circuit fault detection
(Open/short-circuit detection)
Open-circuit < 3.6 mA; short-circuit > 21 mA
0
Open-circuit 1 to 4 mA;
1
short-circuit 20 to 23 mA
6. Response to an input circuit
Output signal linear response
0
Increasing output signal >>>
1
Decreasing output signal <<<
2
Continuation see next page!
English