Automatic closing after either partial or pedestrian opening
By default, the feature is disabled.
To enable it:
Select the DIPs as shown and press the PROG key on the board. The PRG LED stays on and the buzzer sounds off
for 1 s.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
⚠
The automatic closing time is permanently set to 10 seconds.
Pre-flashing (pre-flashing duration: 5 s)
By default, the feature is disabled.
To enable it:
select the DIPs as shown and press the PROG key on the board. The LED stays on and the buzzer sounds off for 1 s.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Closing thrust
By default, the feature is disabled.
To enable it:
select the DIPs as shown and press the PROG key on the board. The LED stays on and the buzzer sounds off for 1 s.
To return to the default setting, press PROG again. The LED flashes and buzzer sounds off twice.
Memorizing the trimmer value
Use the trimmer to adjust the automatic closing time (A.C.T.), the opening and closing final resting point, the second
motor's closing delay time, the gate travel speed, the slow down speed (SP.RAL) and the sensitivity (SENS.).
To memorize the values:
select the DIPs as shown and press the PROG key on the board. The LED stays on and the buzzer sounds off for 1 s.
Services test
By default, the feature is disabled.
To enable it:
Select the DIPs as shown and press the PROG key on the board. The LED stays on and the buzzer sounds off for 1 s.
To return to the default setting, press PROG again. The LED flashes and buzzer sounds off twice.
Button activated maintained action
By default, the feature is disabled.
To enable it:
select the DIPs as shown and press the PROG key on the board. The LED stays on and the buzzer sounds off for 1 s.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off for twice.
⚠
The gate opens and closes when the button is kept pressed.
Opening button connected on 2-3P (contact NO) and closing button connected on 2-7 (contact NO)
All other control devices, even radio-based ones, are excluded.
Partial opening
Select the DIPs as shown and press the PROG key for 1 s. The PRG LED flashes. Within 20 s, enter a code
on the keypad selector or press a button on the transmitter you want to memorize.
Once memorization is finished the PRG LED turns on and the buzzer sounds off for 1 s.
If the transmitter has previously been memorized or the maximum number of registered users is exceeded the
LED flashes quickly and the buzzer sounds off 7 times.
Open only
Select the DIPs as shown and press the PROG key for 1 s. The PRG LED flashes. Within 20 s, enter a code
on the keypad selector or press a button on the transmitter you want to memorize.
Once memorization is finished the PRG LED stays on and the buzzer sounds off for 1 s.
If the transmitter has previously been memorized or the maximum number of registered users is exceededthe
LED flashes quickly and the buzzer sounds off 7 times.
OPEN-CLOSE-INVERT
Select the DIPs as shown and press the PRG key for 1 s. The PRG LED flashes. Within 20 s, enter a code on the
keypad selector or press a button on the transmitter you want to memorize.
Once memorization is finished the PRG LED stays on and the buzzer sounds off for 1 s.
If the code has been previously memorized or the maximum number of registered users exceeded, the LED
flashes quickly and the buzzer sounds off 7 times.
OPEN-STOP-CLOSE-STOP
Select the DIPs as shown and press the PRG key for 1 s. The PRG LED flashes. Within 20 s, enter a code on
the keypad selector or press a button on the transmitter you want to memorize.
Once memorization is finished the PRG LED stays on and the buzzer sounds off for 1 s.
If the code has been previously memorized or the maximum number of registered users exceeded, the LED
flashes quickly and the buzzer sounds off 7 times.
MANAGING UP